Viessmann · Boiler troubleshooting

Refitting the junction box lid, control base, front panel and programming unit (programming unit at bottom)

Vitodens 100-W

What is going on

Reassembly order when the programming unit is mounted at the bottom.

Check in this order

  1. Place the junction box lid on the junction box.
  2. Secure the lid in place with latches.
  3. Release the tabs on the boiler control base.
  4. Pull the control base straight out.
  5. Re-install the control base into the base of the boiler. Only needed if the control base was in service position.
  6. Install the front panel.
  7. Install the programming unit in the control base.
  8. Before fitting the programming unit, remove the WiFi labels from its back and apply label B to the programming unit, one label in these instructions and one in the operating instructions.

Applies to: Vitodens 100-W B1HE/B1KE

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 100-W B1HE/B1KE installation manual, p. 30. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.