Recommended multi-zone hydronic layout with DHW tank and low-loss header

Vitodens 200-W B2HB

What is going on

Reference layout for a Vitodens 200-W with a DHW storage tank, a low-loss header and three zone circuits. A low-loss header is strongly recommended and is sold as an accessory. Zone circuit 1 uses boiler output 157. Zone circuits 2 and 3 use outputs A1 and A2 on the AM1 extension module (accessory). Outdoor, DHW and supply sensors are wired as shown in the legend.

Check in this order

  1. Install the boiler pump on output 20 and the DHW pump on output 21.
  2. Wire the thermostats for zone circuits 1, 2 and 3 as dry contacts.
  3. Connect zone circuit 1 to output 157.
  4. Connect zone circuits 2 and 3 to outputs A1 and A2 on the AM1 extension module.
  5. Mount the outdoor sensor, DHW sensor and supply sensor as shown in the legend.

Applies to: Vitodens 200-W B2HB, system layout 8 (DHW tank, low-loss header, three zone circuits)

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 200-W B2HB 19 to 35, 68 to 125 Installation Instructions, p. 40. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.