Recommended multi-zone hydronic layout with DHW tank and low-loss header
What is going on
Reference layout for a Vitodens 200-W with a DHW storage tank, a low-loss header and three zone circuits. A low-loss header is strongly recommended and is sold as an accessory. Zone circuit 1 uses boiler output 157. Zone circuits 2 and 3 use outputs A1 and A2 on the AM1 extension module (accessory). Outdoor, DHW and supply sensors are wired as shown in the legend.
Check in this order
- Install the boiler pump on output 20 and the DHW pump on output 21.
- Wire the thermostats for zone circuits 1, 2 and 3 as dry contacts.
- Connect zone circuit 1 to output 157.
- Connect zone circuits 2 and 3 to outputs A1 and A2 on the AM1 extension module.
- Mount the outdoor sensor, DHW sensor and supply sensor as shown in the legend.
Applies to: Vitodens 200-W B2HB, system layout 8 (DHW tank, low-loss header, three zone circuits)
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 200-W B2HB 19 to 35, 68 to 125 Installation Instructions, p. 40. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.