Viessmann · Boiler troubleshooting

Pump outputs not powered

Versatronik 10.WB1

What is going on

The unit has power, but the space heating or DHW pump outputs stay off.

Likely causes

  • Blown F2 fuse
  • No space heating or DHW call present
  • No 120VAC signal from the boiler at the WB1 input
  • Loose terminal connection
  • Faulty RT/DHW interconnection between Versatronik 10.WB1 and boiler

Check in this order

  1. Check the F2 fuse.
  2. Confirm a space heating or DHW call is present.
  3. Confirm 120VAC is present at the WB1 input from the boiler.
  4. Verify the terminal connections.
  5. Check the RT/DHW interconnections between the Versatronik 10.WB1 and the boiler.

Applies to: Viessmann Vitodens 100-W, WB1A and WB1B with Versatronik 10.WB1

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Versatronik 10.WB1 installation and operating manual, p. 25. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.