Viessmann · Boiler troubleshooting
Primary pump placement for DHW storage tank layout
What is going on
In system layout 3 the primary pump must pump into the boiler, as illustrated in the manual. The boiler is paired with closely spaced tees or a low-loss header.
Check in this order
- Install the primary pump (L) so it pushes water into the boiler.
- Use closely spaced tees (4x pipe diameter or 12 in / 305 mm) only if a low-loss header is not fitted.
Applies to: Vitodens 100-W WB1B 26 and 35 with DHW storage tank and one heating circuit
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 100-W, WB1B installation manual, p. 40. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.