Viessmann · Boiler troubleshooting

Poor WiFi connection to the boiler

Vitodens 100-W

What is going on

Signal can be weakened by walls, ceilings, metal and nearby electronics.

Likely causes

  • Walls and ceilings weaken the signal.
  • Metal objects, reinforcement, metallized glazing or foil reflect the signal.
  • Service ducts and lift shafts block the signal.
  • Nearby high frequency devices interfere with the signal.
  • Flat (unfavourable) angle of penetration through a wall.

Check in this order

  1. Install the boiler as close as possible to the WiFi router.
  2. Keep at least 6 ft (2 m) from computers, audio and video systems, devices with active WiFi, electronic transformers and pre-ballasts.
  3. Use a WiFi repeater if the signal is still weak.
  4. Check the WiFi signal strength on the boiler display (see operating instructions).
  5. Where possible, have wireless signals pass through walls at a near-vertical angle.

Applies to: Vitodens 100-W B1HE/B1KE

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 100-W B1HE/B1KE installation manual, p. 29. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.