Viessmann · Boiler troubleshooting
Piping examples with Vitotronic controls
What is going on
Layouts for Vitotronic 100 and 200 controls with and without mixing valves and domestic hot water.
Check in this order
- Without a mixing valve (Vitotronic 100, KW10B): include a heating circuit, spring-loaded flow check valve, circulation pump, field-supplied air vent, pressure relief valve and temperature pressure gauge, expansion tank and low water cut-off if required.
- Without a mixing valve and with DHW (Vitotronic 100, KW10B): add an indirect-fired domestic hot water storage tank.
- With one low-temperature circuit and a 4-way mixing valve plus DHW (Vitotronic 200, KW2 with mixing valve actuator kit): add the mixing valve and DHW tank.
- With one low-temperature circuit, one high-temperature circuit and DHW (Vitotronic 200, KW2): add both circuits with the 4-way mixing valve and DHW tank.
Applies to: Vitotronic applications
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitorond 100, VR1 installation and service instructions, p. 42, p. 43, p. 44. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.