Viessmann · Boiler troubleshooting

Piping connections and shutoff valves

Vitotron 100 VLN2

What is going on

Supply and return must not be reversed. Shutoff valves go below the inlet and outlet connections.

Check in this order

  1. Mount the boiler vertically on an even wall using the key hole slots.
  2. Connect the inlet return (blue label) and the outlet supply (red label) to the correct manifolds.
  3. Install shutoff valves below the inlet and outlet connections before plumbing to the system.
  4. Optional gauges can be installed below the boiler.
  5. Install drain valves to help fill, purge and drain the unit.
  6. Install a feed or pressure reducing valve and a backflow preventer if local code requires it.

Applies to: Vitotron 100 VLN2 plumbing

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitotron 100 VLN2 installation and service instructions, p. 8. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.