Viessmann · Boiler troubleshooting

Opening the external accessories box and control unit

Vitodens 200-W B2HA

What is going on

Steps to open the accessory connection box and the control unit for field wiring.

Check in this order

  1. Remove both screws from the front plate of the external accessory connection box and set them aside.
  2. Loosen both retaining screws without removing them.
  3. Pull the accessory connection box forward until the retaining screws clear the guides.
  4. Swing the accessory connection box down.
  5. Tilt the bottom of the box cover forward, lift it past the locating pins and remove it.
  6. Slide both sides of the programming unit cover closed.
  7. Release the hinged hooks on both sides of the control unit.
  8. Lift the control unit cover, then fold the control unit down.
  9. Release the locking tabs and remove the cover.

Applies to: Vitodens 200-W B2HA 80 to 100, 285 to 352

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 200-W B2HA 80 to 100, 285 to 352 Installation Instructions, p. 22-23. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.