Viessmann · Boiler troubleshooting

Open and close the junction box

Vitodens 100-W B1HE/B1KE

What is going on

Procedure to open the junction box to reach the circuit boards, and to reassemble it.

Check in this order

  1. Fold down the red clips and open the front cover of the junction box by turning it.
  2. Push the side clips to the side to unlock the rear cover.
  3. Turn the rear cover out upwards and open it.
  4. Lift out the separation wall vertically from its side guides.
  5. Pull the cables off the PCBs.
  6. Remove the rear cover to expose the circuit boards. Observe the interlock.
  7. Refit in reverse order. When fitting the separation wall, seat it in the side guides and make sure it latches to the rear cover.
  8. Errors in assembly can cause a leaking air box.

Applies to: Vitodens 100-W B1HE/B1KE

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 100-W B1HE/B1KE installation manual, p. 89-90. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.