Viessmann · Boiler troubleshooting

No hot water

Vitotronic 200Vitotronic 300-K

What is going on

DHW is off because the system is off, settings are wrong, or fuel or a fault is the cause.

Likely causes

  • Heating system switched off.
  • Fuse or MCB tripped.
  • DHW heating disabled or DHW temperature/time program wrong.
  • No fuel.
  • Fault active.

Check in this order

  1. Set ON/OFF switches at all control units to ON.
  2. Turn on the mains isolator if installed and check the fuse/MCB.
  3. On the 300-K, make sure DHW heating is enabled and check DHW temperature, time and time program.
  4. Check remote control settings if fitted.
  5. Check the fuel supply (see fuel guidance on p. 43).
  6. If a fault shows, scan and note the code, acknowledge it, and notify the contractor.

Applies to: Vitotronic 200 and 300-K

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitotronic 200 and 300-K Operating Instructions, p. 37. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.