Viessmann · Boiler troubleshooting

No DHW (domestic hot water)

Vitotronic 300-K

What is going on

Check power, fuel and DHW settings. Also check for a fault display.

Likely causes

  • Heating system is off
  • Control unit or remote control set incorrectly
  • DHW heating not enabled
  • No fuel supply
  • Fault shown on display

Check in this order

  1. Switch on the ON/OFF switch on the control units, the mains isolator if installed, and the MCB in the distribution board.
  2. Check operating program, DHW temperature, DHW time program and time.
  3. For LPG, check fuel reserves. For natural gas, open the gas shut-off valve and check with the gas utility if needed.
  4. If a fault is shown, check its type, acknowledge it, and notify the heating contractor if necessary.

Applies to: DHW heating

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitotronic 300-K MW2C operating instructions, p. 29. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.