Viessmann · Boiler troubleshooting
Mounting the wall base and fitting the room controller
What is going on
Mount the base at about eye level and wire it to the boiler OT-BUS. Terminals 1+2 are the bus and can be swapped because the connector is polarity-protected. Terminals 3+4 are for the remote telephone switch and 5+6 for the outdoor sensor, both optional. Terminal 1 is on the left.
Check in this order
- Fix the base to the wall at about eye level.
- Connect terminals 1+2 on the base to the OT-BUS terminals on the boiler. The polarity can be swapped.
- Connect the remote telephone switch to terminals 3+4 if one is used.
- Connect the outdoor sensor to terminals 5+6 if one is used.
- Snap the top part on hook it in at the centre of the top edge, pivot it down onto the base and press it on.
- To remove, lever the cover off from the underside with a screwdriver, then pivot the top upwards.
Applies to: Versatronik COMO OT wall base and cover
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Versatronik COMO OT manual, p. 8. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.