Viessmann · Boiler troubleshooting
Mounting the Versatronik 10.WB1 device
What is going on
Mount the device on an adjacent wall. The cover comes off by loosening the two screws on either side of the base. Pull out the knockouts you need for field wiring, and use the plug-in connectors for the low voltage side.
Check in this order
- Loosen the two screws on either side of the base and remove the cover.
- Fasten the base to the wall with field-supplied screws or fasteners.
- Remove the knockout and fit a strain relief or box connector for the line voltage entry. Remove the other knockouts you need for connections.
- Remove the knockout on the right side for the low voltage connections to the right side of the PCB and use the supplied plug-in connectors.
- After all 120VAC and low voltage wiring is complete and checked, refit the cover.
Applies to: Versatronik 10.WB1 device
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Versatronik 10.WB1 installation manual, p. 9. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.