Viessmann · Boiler troubleshooting

Mount oil burner on combustion chamber door

Vitorond 100VR1

What is going on

Mount the flange and burner per the burner instructions. For Riello tube insert adjustment, see the calibration chart on p. 38.

Check in this order

  1. Remove the burner from the carton. The mounting flange is factory installed.
  2. Mount four M8 spacer bolts in the threaded holes of the combustion chamber door.
  3. Slide the burner gasket over the spacer bolts.
  4. Mount the burner as shown.
  5. Secure the burner with the M8 nuts and washers provided.
  6. Set the burner air tube insertion per the burner manufacturer's instructions.

Applies to: Oil burner mounting

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitorond 100 VR1 installation and service manual, p. 24. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.