Viessmann · Boiler troubleshooting
Lighting and starting the appliance
What is going on
Start-up sequence from the lighting label. The appliance has an ignition device and has no pilot, so do not light it by hand.
Check in this order
- Set the thermostat or other control to the lowest setting.
- Turn off all electric power to the appliance.
- Close the main gas shut-off valve.
- Wait five minutes to clear any gas, then smell for gas including near the floor.
- If gas is smelled, stop and follow the gas smell response steps.
- Open the main gas shut-off valve.
- Turn on all electric power to the appliance.
- Set the thermostat or control to the desired setting.
- If the appliance will not operate, turn off the gas as described and call a service technician or the gas supplier.
Applies to: Vitodens 200-W B2HB 19 to 35, 68 to 125
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 200-W B2HB installation manual, p. 61. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.