Viessmann · Boiler troubleshooting
Lighting and operating instructions (gas appliance with ignition device)
What is going on
Procedure from the owner label for lighting the boiler and shutting off gas. The boiler has no pilot and lights automatically.
Check in this order
- Set the thermostat or control to lowest setting.
- Turn off all electric power to the boiler.
- Close the main manual gas shut-off valve.
- Wait five minutes to clear any gas, then smell for gas near the floor.
- If gas is smelled, stop and do not operate any switch or phone in the building; get out and call the gas supplier from outside.
- If no gas is smelled, open the main manual gas shut-off valve.
- Turn on electric power to the boiler.
- Set the thermostat or control to the desired setting.
- If the boiler will not operate, shut off gas to the appliance and call the service technician or gas supplier.
- To shut off gas set control to lowest, turn off power if service is needed, then close the main manual gas shut-off valve.
- Use only hand force on the gas control; do not use tools. Do not operate the boiler if any part has been under water.
Applies to: Vitodens 200-W B2HB 45, 57, 160, 199
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 200-W B2HB 45, 57, 160, 199 Service, p. 102. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.