Installing the safety (pressure relief) valve
What is going on
Fit the factory relief valve and gauge on the boiler using a brass adapter.
Check in this order
- Screw the safety valve onto the brass adapter and tighten.
- Screw the pressure gauge onto the brass adapter.
- Fit the adapter to the boiler with the retaining clip.
- Secure the clip with a cable tie.
- Route the discharge pipe to a floor drain, ending about 6 in. (150 mm) above it.
- Do not install an isolation valve between the boiler and the relief valve.
Applies to: Vitodens 100-W B1HE/B1KE relief valve
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 100-W, B1HE/B1KE Installation/Service, p. 23. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.