Installation in marine (salt air) environments
What is going on
Boilers in damp, salty coastal areas corrode faster on exposed metal parts such as the casing and fan housing. Do not use a direct vent (outdoor air) system in these locations. Use a room-air-dependent vent system so the boiler takes indoor air, which has lower humidity.
Likely causes
- Chloride from sea spray combined with humidity
Check in this order
- Identify whether the site is a damp, salty coastal area.
- Do not install a direct vent system that draws outdoor air.
- Install a room-air-dependent vent system.
Applies to: Vitodens 100-W B1HE and B1KE, coastal sites
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 100-W B1HE/B1KE installation manual, p. 8. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.