Installation example: low-loss header with mixing valve circuits
What is going on
Boiler with a low-loss header, several heating circuits using mixing valves, one circuit without a mixing valve, and a DHW tank. Designs of this type should be reviewed with a Viessmann sales representative.
Check in this order
- Use a Vitotronic 200 outdoor reset control with KW6B on the boiler.
- Fit the boiler pump (20) and the heating circuit pumps.
- Use an accessory kit for each heating circuit with a mixing valve, with a mixing valve temperature sensor.
- Install the low-loss header with its temperature sensor if required.
- Locate the expansion tank as shown in the drawing.
- Fit a temperature and pressure relief valve and a pressure relief valve as shown.
- Separate the system from underfloor tubing that has no oxygen barrier.
Applies to: Single Vitocrossal 300 CU3A with low-loss header and mixing valves
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocrossal 300 CU3A technical data manual, p. 25. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.