Viessmann · Boiler troubleshooting
Install the control unit front (VD2/VD2A/CT3)
What is going on
Reattaching the front housing of the Vitotronic 100 GC1 after wiring.
Check in this order
- Position the front housing and clip the hinges onto the main housing.
- Release the stay bar, open it up and lock it at point A.
- Insert the flat cable from the Optolink into plug X20.
- Insert the programming unit plug into plug X10 and route the cable through the cover guides.
- Engage the stay bar in the front housing.
- Close the front housing.
- Secure the front housing with the supplied screws.
- Install the connection enclosure cover and secure it with the supplied screw.
Applies to: Vitotronic 100 GC1 on VD2/VD2A/CT3 boilers
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotronic 100 GC1 / Vitocontrol-S VD2/CT3/CM2 installation manual, p. 68. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.