Viessmann · Boiler troubleshooting
Inspection and maintenance intervals
What is going on
Service intervals for the boiler, DHW tank and accessories as listed by Viessmann.
Check in this order
- Service the heating system at least every 2 years by an authorised contractor.
- Clean the boiler annually, as contamination raises flue gas temperature and energy losses.
- Clean the DHW tank and DHW connections no later than 2 years after commissioning and as needed; only a qualified contractor should clean inside the tank.
- On Vitocell 100 tanks, have the sacrificial anode checked annually with an anode tester.
- Check the DHW tank safety valve every six months by venting it; the outlet must not be closed off.
- Replace the filter element on non-back-flushing potable water filters every six months and inspect it every two months.
- Back-flush back-flushing potable water filters every two months.
- Replace damaged cables or lines only with Viessmann cables or lines through a qualified contractor.
- Clean the controls with a non-scouring domestic cleaning agent and the microfibre cloth supplied.
Applies to: Vitotronic 300-K system with boiler, DHW tank and potable water filter
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotronic 300-K MW2C operating instructions, p. 30. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.