Viessmann · Boiler troubleshooting

Inspection and maintenance intervals

Vitotronic 300-K

What is going on

Service intervals for the boiler, DHW tank and accessories as listed by Viessmann.

Check in this order

  1. Service the heating system at least every 2 years by an authorised contractor.
  2. Clean the boiler annually, as contamination raises flue gas temperature and energy losses.
  3. Clean the DHW tank and DHW connections no later than 2 years after commissioning and as needed; only a qualified contractor should clean inside the tank.
  4. On Vitocell 100 tanks, have the sacrificial anode checked annually with an anode tester.
  5. Check the DHW tank safety valve every six months by venting it; the outlet must not be closed off.
  6. Replace the filter element on non-back-flushing potable water filters every six months and inspect it every two months.
  7. Back-flush back-flushing potable water filters every two months.
  8. Replace damaged cables or lines only with Viessmann cables or lines through a qualified contractor.
  9. Clean the controls with a non-scouring domestic cleaning agent and the microfibre cloth supplied.

Applies to: Vitotronic 300-K system with boiler, DHW tank and potable water filter

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitotronic 300-K MW2C operating instructions, p. 30. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.