Viessmann · Boiler troubleshooting

Heating water and DHW connections

Vitodens 200-W B2HB

What is going on

Flush the heating system before connecting the boiler, especially when adding it to an existing system. Field-supplied nipples and tees are used for the DHW supply and return. The boiler must not be exposed to pressures or temperatures above the listed limits.

Check in this order

  1. Thoroughly flush the heating system (especially before connecting to an existing system).
  2. Connect the boiler supply and return and the DHW supply and return (DS and DR) as shown.
  3. Use field-supplied nipples and tees for the DHW connections.
  4. Apply enough thread sealant (supplied) to all connections.
  5. Do not expose the boiler to pressures or temperatures above the listed maximums.

Applies to: Vitodens 200-W B2HB 45, 57, 160, 199

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 200-W B2HB installation manual, p. 20. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.