Viessmann · Boiler troubleshooting

Heating circuit remains cold

Vitotronic 200-H

What is going on

The heating circuit stays cold even though the system is powered.

Likely causes

  • Power supply is switched off.
  • Fuse in the domestic power circuit or control panel has blown or tripped.
  • Time is set incorrectly.
  • Heating program w or 9 is selected (button lit).
  • DHW-only system: domestic hot water has priority (w shows in the display).
  • Mixing valve was closed by the master control.

Check in this order

  1. Switch on the power supply.
  2. If a fuse has blown or tripped, inform the heating contractor.
  3. Set the correct time (page 22).
  4. Set heating program rw (page 10).
  5. Wait until the DHW tank has heated up and w goes out.
  6. Wait until the mixing valve reopens.

Applies to: Vitotronic 200-H HK1S/HK3S

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitotronic 200-H operating instructions, p. 30. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.