Viessmann · Boiler troubleshooting
Heating circuit remains cold
What is going on
The heating circuit stays cold even though the system is powered.
Likely causes
- Power supply is switched off.
- Fuse in the domestic power circuit or control panel has blown or tripped.
- Time is set incorrectly.
- Heating program w or 9 is selected (button lit).
- DHW-only system: domestic hot water has priority (w shows in the display).
- Mixing valve was closed by the master control.
Check in this order
- Switch on the power supply.
- If a fuse has blown or tripped, inform the heating contractor.
- Set the correct time (page 22).
- Set heating program rw (page 10).
- Wait until the DHW tank has heated up and w goes out.
- Wait until the mixing valve reopens.
Applies to: Vitotronic 200-H HK1S/HK3S
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotronic 200-H operating instructions, p. 30. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.