Viessmann · Boiler troubleshooting

Heat does not circulate through the boiler

Vitotron 100 VLN2

What is going on

The boiler is blocked by air or the pump or flow sensor has failed.

Likely causes

  • Air bubble trapped in the system, pump or boiler
  • Fuse on the control panel blown
  • Pump or flow sensor failure

Check in this order

  1. Purge the installation, the pump and the boiler of air.
  2. Check the 1 amp fuse on the control panel.
  3. Check the power supply to the circulating pump.
  4. If the pump or flow sensor has failed, contact an authorized service person or the seller.

Applies to: Vitotron 100 VLN2

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitotron 100 installation and service instructions, p. 18. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.