Hang the boiler on the wall bracket
What is going on
Remove the external accessories connection box cover, loosen the bottom screws without fully removing them, remove the front enclosure panel, hang the boiler on the bracket, and level it with the levelling screws. Level both vertically and horizontally so condensate drains properly. Fit the supplied installation fittings per the layout.
Check in this order
- Remove the external accessories connection box cover.
- Loosen the bottom screws without removing them.
- Lift the front enclosure panel up and pull it away from the boiler.
- Mount the boiler onto the bracket.
- Adjust the levelling screws until a round bubble level on top of the boiler reads level.
- Install the supplied installation fittings per the layout on page 11.
- Check that the boiler is level both ways so condensate drains.
Applies to: Vitodens 200-W B2HA 80 to 100, 285 to 352
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 200-W B2HA installation instructions, p. 15. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.