Gas piping leak and pressure test

Vitodens 100-W B1HE/B1KE

What is going on

Test the gas supply piping before putting the boiler in service. Isolate the boiler correctly for the test pressure used.

Check in this order

  1. Close the boiler's individual manual gas shutoff valve for tests at or below ½ psig (14 in. w.c.).
  2. Disconnect the boiler and its shutoff valve from the piping for any test above ½ psig (14 in. w.c.).
  3. Brush an approved liquid leak solution on all joints. Keep it off electrical parts, wires and connectors.
  4. Keep leak solution away from the gas valve regulator and its vent opening.
  5. Repair every leak found.
  6. Purge air from the gas line.

Applies to: Vitodens 100-W B1HE/B1KE gas connection

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 100-W, B1HE/B1KE Installation/Service, p. 18. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.