Viessmann · Boiler troubleshooting

Free-standing boiler stand

Vitodens 200-W B2HB

What is going on

The boiler stand is for free-standing installation of one boiler. The wall location for the frame, bracket and vents must be calculated in the field, since no template is supplied.

Check in this order

  1. Fasten the stand securely to the floor using concrete expansion anchors, Hilti KB-TZ or equivalent.
  2. Attach the wall mounting bracket to the mounting frame with the supplied hardware.
  3. Check the wall bracket is level.
  4. Move the frame into position and secure it to the floor, and to the wall if needed.

Applies to: Free-standing single boiler

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 200-W B2HB 19 to 35, 68 to 125 installation instructions, p. 16. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.