Flue system conditions before commissioning

Vitodens 100-W B1HE/B1KE

What is going on

Commissioning may only start when the flue and air supply conditions are met.

Check in this order

  1. Confirm unrestricted flow in the flue gas routes.
  2. Confirm the positive pressure flue system is gas-tight.
  3. Check inspection port covers are secure and tight.
  4. Confirm combustion air openings are open and cannot be closed.
  5. Confirm all local flue and commissioning regulations are followed.
  6. Fit the coaxial vent seal if the boiler is direct vent on a two-pipe system.
  7. Vents for combustion air must be non-closable and wind protected to stop condensate draining.

Applies to: Vitodens 100-W B1HE/B1KE flue system

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 100-W, B1HE/B1KE Installation/Service, p. 24. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.