Viessmann · Boiler troubleshooting
External blocking
What is going on
External contact blocks heating operation. A version with fault message input is also available.
Check in this order
- Wire the floating contact to DE1, DE2 or DE3.
- Set the input to 3A:3, 3B:3 or 3C:3 for blocking, or 3A:4, 3B:4 or 3C:4 for blocking with fault message.
- Set pump response with 3E (internal pump), D6 (heating circuit pump) and 5E (DHW circulation pump).
Applies to: Vitodens 200-W B2HA 80 to 100
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 200-W B2HA Service Instructions, p. 89-90. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.