Electric boiler does not heat

Vitotron 100 VLN2

What is going on

The boiler is not heating even though the panel is working. Causes include the utility off-peak signal and sensor or panel failures.

Likely causes

  • Electric utility off-peak signal is not present
  • Cylinder temperature sensor or thermostat failure
  • Control panel failure

Check in this order

  1. If the off-peak signal is blinking the heating status, confirm the utility off-peak control is calling for heat.
  2. Have an authorized service person replace the cylinder temperature sensor or thermostat if it has failed.
  3. Contact an authorized service person if the control panel has failed.

Applies to: Vitotron 100 VLN2

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitotron 100 installation and service instructions, p. 18. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.