DHW not heating as expected
What is going on
Checklist for when hot water is not heated when required. The control unit is set so DHW heating applies to all heating circuits by default.
Likely causes
- DHW set temperature is not set to the required value.
- Heating program for the circuit is not set to "Heating and DHW" or "Only DHW".
- DHW time program does not cover the time hot water is needed.
Check in this order
- Check the DHW set temperature and set it if needed.
- Check that the heating program is "Heating and DHW" (with central heating) or "Only DHW" (summer mode).
- Check the DHW time program and adjust the time phases if needed.
- Contact the heating contractor before changing the default DHW settings that apply to all heating circuits.
Applies to: Vitotronic 300-K, MW1B
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotronic 100/300-K operating instructions, p. 20. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.