Viessmann · Boiler troubleshooting

DHW is too hot

Vitotronic 200Vitotronic 300-K

What is going on

DHW temperature setting is too high, solar may be heating the tank, or test mode is on.

Likely causes

  • DHW temperature set too high.
  • DHW heated by solar thermal system.
  • Emissions test mode enabled.

Check in this order

  1. Check and correct the DHW temperature.
  2. If solar heats the DHW, check settings at the solar control unit.
  3. End emissions test mode if it is on.

Applies to: Vitotronic 200 and 300-K

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitotronic 200 and 300-K Operating Instructions, p. 36. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.