Viessmann · Boiler troubleshooting

Convert the boiler from natural gas to LPG

Vitodens 100-W B1HE/B1KE

What is going on

Gas type change is done in the control settings; the gas solenoid valve is not mechanically adjusted.

Check in this order

  1. Change the gas type to Propane in the commissioning assistant.
  2. Do not make any mechanical adjustment to the gas solenoid valve.
  3. Affix the field conversion label and the gas type label as shown, next to the CSA rating plate.
  4. Record the gas type in the maintenance record.

Applies to: Conversion to LPG

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 100-W, B1HE/B1KE Combi Installation/Service instructions, p. 45. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.