Viessmann · Boiler troubleshooting
Control calls for heat but the burner does not respond
What is going on
The control is calling for heat but the burner stays off.
Likely causes
- Burner is faulty and will not reset
- Power venter has no separate 120 VAC supply to its motor
- Air proving switch, blower wheel or timer/relay in the power venter is defective
- Another accessory is defective
Check in this order
- Try to reset the burner with the reset button under the burner hood. Service the burner if needed and check the burner manual troubleshooting section.
- Make sure the power venter has its own 120 VAC supply to the motor. Check the power venter manual troubleshooting section.
- Check that all accessories work properly and replace any that do not. Use the accessory literature for guidance.
- If the F1 fuse has blown, replace it.
Applies to: Vitotronic 100 KW10B
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotronic 100 KW10B operating manual, p. 8. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.