Viessmann · Boiler troubleshooting

Connect the low-loss header sensor to the X3 plug

Vitodens 200-W B2HB

What is going on

The low-loss header sensor connects to the boiler control board on terminals X3.4 and X3.5. The control unit cover must be removed to reach the X3 plug, then refitted after the work.

Check in this order

  1. Disconnect power to the boiler.
  2. Remove the control unit cover (see the cover removal reference on p. 23 of the manual).
  3. Remove the X3 plug from the control board.
  4. Connect the low-loss header sensor to terminals X3.4 and X3.5 (if a low-loss header is used).
  5. Install other required sensors as instructed.
  6. Reinstall the X3 plug and the control cover.

Applies to: Vitodens 200-W B2HB with low-loss header

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 200-W B2HB 19 to 35, 68 to 125 Installation Instructions, p. 48. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.