Viessmann · Boiler troubleshooting
Connect several remote controls via a terminal box (version 1)
What is going on
Use an on-site terminal box when more than one remote control is connected to the control unit.
Check in this order
- Install a terminal box on site.
- Connect the control unit and each Vitotrol unit to the terminal box as shown in the diagram.
- Keep each remote control branch within 15 m / 50 ft.
- Keep the total KM BUS cable length within 50 m / 164 ft.
Applies to: Vitotrol remote controls on KM BUS
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocontrol-S VD2/CT3/CM2 installation and service instructions, p. 150. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.