Viessmann · Boiler troubleshooting
Connect DHW storage tank temperature sensor
What is going on
The DHW tank sensor is needed when a stand-alone DHW storage tank is used with the boiler. Only the sensor is supplied; other piping is field supplied.
Check in this order
- For Vitocell 100 or 300 tanks, locate the DHW sensor well and install the DHW temperature sensor following the tank's installation instructions.
- For a non-Viessmann tank, check with the tank manufacturer that the Viessmann DHW sensor will operate correctly.
- Install a temperature tempering valve in the DHW supply line (strongly recommended by Viessmann).
- Apply sufficient thread sealant when making DHW connections.
- Set the system coding per the Service Instructions.
Applies to: Vitodens 200-W B2HB DHW tank
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 200-W B2HB installation manual, p. 21. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.