Connect CombiPLUS cables to the boiler power pump module

Vitodens 100-W WB1B

What is going on

Wiring of the control cable Q and pump cable R inside the power pump module.

Check in this order

  1. Route control cable Q through the fourth hole of the power pump module base and pump cable R through the second hole. Secure both with the locknuts.
  2. Connect pump cable wire BK1 (neutral) to the power pump neutral on terminal block X3.
  3. Connect pump cable wire BK2 (line) to the power pump line on terminal block X3.
  4. Connect the green/yellow ground wire to any open terminal on terminal block X2.
  5. Plug the DHW temperature sensor / flow sensor (5-pin) into plug-in X7.
  6. Plug the diverter valve (6-pin) into plug-in X10.
  7. Fit the supplied anchors behind the cables, fix the conduit clip with its screw, and press cables Q and R into the clip.
  8. Check the wiring diagram for additional wiring details and the CombiPLUS connections on page 29.

Applies to: Vitodens 100-W WB1B with CombiPLUS

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 100-W, WB1B CombiPlus Installation & Service Instructions, p. 32. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.