Connect an external 0-10 V boiler temperature signal

Vitodens 200-W B2HB

What is going on

An external 0-10 V signal sets the maximum boiler water temperature. The signal must match the chart in the manual.

Check in this order

  1. Connect the external 0-10 V signal to the 0-10V plug on extension module EA1.
  2. Check that the polarity is correct.
  3. Use the chart in the manual to find the maximum boiler water temperature for the signal.
  4. Example from the manual 8 VDC = 176 ºF (80 ºC).

Applies to: Models 45, 57, 160, 199

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 200-W B2HB installation instructions, p. 51. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.