Viessmann · Boiler troubleshooting
Clearances to combustibles and venting
What is going on
The Vitodens 100-W is listed for zero clearance to combustibles on the sides, top, front, rear and vent pipe when vented with a single-wall AL-29-4C special venting system or UL/ULC-listed CPVC gas vent. This listing overrides the clearance on the vent label. Allow 12 in. (30 cm) above the top for the vent. Alcove and closet installations are also listed at zero clearance. Refer to the Vitodens Venting System instructions for details.
Check in this order
- Use only the listed vent material (AL-29-4C single-wall or UL/ULC-listed CPVC).
- Keep at least 12 in. (30 cm) above the boiler top for venting.
- Follow the Vitodens Venting System instructions for the vent pipe.
Applies to: Vitodens 100-W B1HE and B1KE
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 100-W B1HE/B1KE installation manual, p. 10. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.