Viessmann · Boiler troubleshooting
Clearances to combustibles and service access
What is going on
Values read from the clearance tables. The printed table layout is jumbled in the text, so confirm each figure against the page before use.
Check in this order
- Standard installation keep the rear 6 in (150 mm) and flue 9 in (230 mm) from combustibles. Sides are 0 in.
- Floor combustibles confirm the rear, side, flue and top values on the printed table.
- Alcove installation allow 24 in (610 mm) for burner service.
- Keep the minimum service access shown in the recommended clearances for service diagram for cleaning and service.
Applies to: VR1 22 to 33, 91 to 140
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitorond 100 installation and service manual, p. 12. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.