Cleaning the burner fan, Venturi tube and burner tube
What is going on
Cleaning the fan and burner assembly and checking for gas leaks after reassembly.
Likely causes
- Dirt on the fan impeller or housing.
- Gasket between fan housing and burner plate damaged.
Check in this order
- Close the central gas shut-off valve before any burner work.
- Disconnect the Venturi mixing tube from the fan.
- Detach the Venturi mixing tube with the combination gas valve and gas connector pipe; detach connector pipes if needed.
- Detach the connector pipes from the fan and remove the fan.
- Clean the fan housing and impeller with compressed air.
- Vacuum the burner tube inside and out if necessary.
- Reassemble in reverse order and fit the gasket between fan housing and burner plate in the correct position. Replace it if damaged.
- Check for gas leakage at the screws and at the gasket between the fan housing and the burner plate.
Applies to: Vitocrossal 300 CA3B Dual Fuel burner fan and Venturi
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocrossal 300 CA3B Dual Fuel Series 2.5 to 6.0 Service Instructions, p. 72. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.