Viessmann · Boiler troubleshooting

Clean condensate siphon (P-trap)

Vitodens 100-W, WB1B

What is going on

Keep the condensate siphon clear so condensate drains freely.

Likely causes

  • Blocked siphon
  • Condensate not draining freely

Check in this order

  1. Check the siphon for unimpeded drainage.
  2. Remove all hoses from the siphon.
  3. Release the locking tabs underneath and lift the siphon out.
  4. Clean the siphon and reinstall it.
  5. Refit all hoses and secure the drain hose with cable ties.
  6. Fill the siphon by pouring 0.3 L (10 fl. oz.) of water into the combustion chamber.

Applies to: Vitodens 100-W, WB1B

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Viessmann Vitodens 100-W, WB1B installation and service instructions, p. 69. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.