Choosing a location for the Vitotrol 200A room sensor
What is going on
The remote unit has a built-in room sensor for room temperature control. Mount it on an internal wall in the main living space, about 5 ft (1.5 m) above the floor. Keep it away from windows, doors, radiators, direct sun, fireplaces and TV sets. Do not add other controllers in that room, and keep the radiator valves in that room fully open. The sensor has no adjustment of its own; room temperature settings are made on the control unit's programming unit or on the remote control.
Check in this order
- Mount the unit on an internal wall about 5 ft (1.5 m) above the floor.
- Keep it clear of windows, doors, radiators, direct sun, fireplaces and TV sets.
- Do not install other controllers in the same room.
- Fully open the thermostatic valves on radiators in that room.
Applies to: Vitotrol 200A remote control, room temperature dependent control
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotrol 200A installation, operating and service instructions, p. 4. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.