Choosing a location for the Vitotrol 200 remote control
What is going on
Pick a room-sensing spot that reads true room temperature. Mount it on an inside wall of the main living area about 1.5 m (5 ft) above the floor. Keep it away from windows, doors, radiators and heat sources such as direct sun, fireplaces and TVs. If the room has other heating controls, or radiator thermostat valves, those must be fully open or removed from the control scheme. Keep the remote control cable away from line-voltage wiring.
Check in this order
- Mount on an inside wall of the main living area, about 1.5 m (5 ft) above the floor.
- Keep away from windows, doors, radiators and heat sources.
- Keep radiator thermostat valves in that room fully open.
- Route the remote control cable separately from line-voltage wiring.
Applies to: Vitotrol 200 remote control with room temperature sensing
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotrol 200 installation instructions, p. 1. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.