Viessmann · Boiler troubleshooting
Chimney and vent requirements
What is going on
Improper sizing, termination or blockage can send flue gases into the living space and cause carbon monoxide poisoning.
Likely causes
- Blocked vent or chimney from birds' nests, ice, snow, debris or other material
- Improper sizing or termination
- Unlined chimney
- Excess depressurization from exhaust devices
- Chimney draft below the mildest weather draft
Check in this order
- Use only approved vent material and install the vent to all applicable local and national codes.
- Use a masonry, concrete or metal chimney built to code. Factory built chimneys must be listed and installed to the manufacturer's instructions.
- Make sure the chimney is clean-out equipped with a tight removable cap that stops air entering.
- Do not connect this boiler to an unlined chimney.
- Inspect the chimney for material, condition and size.
- Connect the oil appliance to its own chimney vent used for no other appliance, unless the codes allow otherwise.
- Do not connect the vent connector to any positive pressure mechanical draft system.
- Inspect the house for exhaust devices that could depressurize it, and tell the owner in writing if they could affect the boiler.
- Confirm chimney draft in cold weather testing and during mild weather.
- Keep sufficient fresh air supplied to the room for combustion.
Applies to: VR1 22 to 33, 91 to 140
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitorond 100 installation and service manual, p. 14. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.