Viessmann · Boiler troubleshooting

Checking flue gas temperature sensor

Vitodens 200-W B2HA

What is going on

Flue gas sensor locks the appliance when the maximum flue gas temperature is exceeded. Unlock by pressing reset button R after the vent system has cooled down. Sensor resistance chart is not legible in this extract.

Likely causes

  • Flue gas temperature sensor out of range or damaged

Check in this order

  1. Remove cables from flue gas temperature sensor A.
  2. Check sensor resistance and compare with the curve.
  3. Replace the sensor if severe deviation.

Applies to: Vitodens 200-W B2HA 45, 60

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 200-W B2HA 45, 60 Service Instructions, p. 79. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.