Checking flue gas temperature sensor
What is going on
Flue gas sensor locks the appliance when the maximum flue gas temperature is exceeded. Unlock by pressing reset button R after the vent system has cooled down. Sensor resistance chart is not legible in this extract.
Likely causes
- Flue gas temperature sensor out of range or damaged
Check in this order
- Remove cables from flue gas temperature sensor A.
- Check sensor resistance and compare with the curve.
- Replace the sensor if severe deviation.
Applies to: Vitodens 200-W B2HA 45, 60
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 200-W B2HA 45, 60 Service Instructions, p. 79. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.