NTI · Boiler troubleshooting

Check water and gas piping

TRX

What is going on

With the cover off the TRX150, I always walk the piping before anything else. Most callbacks I see on boilers trace back to a slow weep at a fitting or tired glycol, and both are easy to catch on a visual. The gas side is a different story, and any smell means stop and call a qualified tech.

Likely causes

  • Slow leak at a water connection, pump flange or fitting
  • Water or antifreeze mix gone acidic or old, with pH below the manufacturer limit
  • Different antifreeze types mixed in the loop

Check in this order

  1. Remove the boiler cover and perform a gas leak check. If you find a gas odor or a leak, call a qualified service technician.
  2. Check the boiler water connections, heat exchanger and external piping, pumps and fittings for leaks. Have leaks repaired at once.
  3. Check the pH of the water or antifreeze mix regularly and replace it when it falls below the manufacturer limit.
  4. Do not mix different types of antifreeze.
  5. Look for stains, crusting or damp insulation, which show slow leaks.

Applies to: TRX150

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: NTI TRX150 manual, p. 89. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.