Viessmann · Boiler troubleshooting

Check the flue gas flapper

Vitodens 200-W B2HA

What is going on

Inspect the flapper behind the fan.

Check in this order

  1. Undo three screws and remove fan A.
  2. Remove the flue gas flapper B.
  3. Check the flapper and gasket for dirt and damage. Replace as needed.
  4. Refit the flapper and the fan with three screws. Torque 2.2 lb.ft. (3.0 Nm).

Applies to: Vitodens 200-W B2HA 19, 28, 35

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Viessmann Vitodens 200-W B2HA service instructions, p. 21. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.