Viessmann · Boiler troubleshooting
Check safety valves, low water cut-offs and pumps
What is going on
Check that the safety devices and pumps work correctly.
Check in this order
- Ensure proper operation of low water cut-offs (if fitted), the pressure relief valve and pumps.
- Check the pressure gauge, air vent and pressure relief valve.
- Confirm the relief valve does not leak and operates as the original manufacturer specifies.
- Refer to the maintenance instructions supplied with low water cut-offs, pumps and zone valves.
- Flush float-type low water cut-offs if used.
- Follow local rules for backflow preventers. Lubricate oil-lubricated pumps as required.
Applies to: Vitodens 100-W, WB1B
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Viessmann Vitodens 100-W, WB1B installation and service instructions, p. 71. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.